Test beam data from first FE-I3 modules have been analyzed (Attilio Andreazza).
Tested modules are:
Position
|
PLL
|
Module #
|
Lab + comments
|
| 1 |
5 |
510896 |
Bonn - Cis+IZM barrel |
| 2 |
2 |
510903 |
Genova - Cis+AMS high leakage current |
| 3 |
3 |
510929 |
Genova - Cis+AMS reworked - first runs |
| 3 |
3 |
510805 |
Bonn - Cis+IZM barrel - second part |
| 4 |
4 |
510733 |
LBL - Cis+AMS disks |
For all the modules (except 510805) the in-time efficiency
was measured for standard configurations and results were
quite uniform.
Tipical in-time efficiency as a function of time (in ns -
please intend x-axis label as "ns") is shown
here.
Besides the excellent result obtained,
we can anticipate that real efficiency is higher than the value
shown in the plot, since there is clear indication that
about half of the missing hits
are correlated between modules. This is due to trigger beam
particles out
of the telescope acceptance. They will be recovered by reconstructing
tracks with DUTs.
Other studies:
TDC calibration for modules: 510733,
510903,
510805.
TOT comparison.
Pixel Testbeam Home Page
C.T.